Catalog No - X075

048A11O11063
Image differs from product
Features
  • Open end brackets, 2 1/4” Resilient rings
  • 1/2” x 5” long shaft with two flats 4.50” 90O apart
  • Automatic reset thermal protector
  • Weather resistant reversing plug
  • Reversible by reconnection
  • 36” long leads
  • Extended thru-bolts, 8-32 1/2” on drive end, 3/4” on non-drive end
  • Capacitor not included, see Accessories section
List Price: $312 USD

Visit Marathon Motors

How can we improve our Product Information?
General Specifications

Model : 048A11O11063 Catalog No : X075
Part Description : 3/4,1140,OPAO,48Y,1/60/208-230 Category : Direct Drive
Stock : Yes
Nameplate Specifications

Output HP : 0.75 HP Output KW : 0.56 kW
Frequency : 60 Hz Voltage : 208-230 V
Current : 4.1-3.8 A Speed : 1075 RPM
Service Factor : 1 Phase : 1
Efficiency : 68.4 % Duty : Continous
Insulation Class : B Design Code : NO DESIGN CODE
KVA Code : F Frame : 48Y
Enclosure : Open Air Over Overload Protector : Automatic Lock Rotor Only
Ambient Temperature : 40 °C Drive End Bearing Size : 6203
Opp Drive End Bearing Size : 6203 UL : Recognized
CSA : Y CE : N
IP Code : 10
Technical Specifications

Electrical Type : Permanent Split Capacitor Starting Method : Across The Line
Poles : 6 Rotation : Selective Counterclockwise
Mounting : Resilient Ring - Extended Studs Motor Orientation : Horizontal
Drive End Bearing : Ball Opp Drive End Bearing : Ball
Frame Material : Rolled Steel Shaft Type : Single Special Extension
Overall Length : 12.22 in Frame Length : 5.50 in
Shaft Diameter : 0.500 in Shaft Extension : 5 in
Assembly/Box Mounting : F1 Only UPC : 722856041890
Weight : 22.00 LB
Speed Characteristics

Curvepoint Current (Amps) Current (%) Torque (ft-lbs) Torque (%) Speed (RPM) Rated Output (KW) Power Factor (%) Rated Output (Hp)
Locked-Rotor 12.25 326.0 29.00 52.0 0 2.27 80.7 0.75
Pull-Up 12.21 325.0 27.80 50.0 114 2.26 80.3 0.75
Full Load 3.76 100.0 56.00 100.0 1,125 0.82 94.7 0.75
Break-Down 8.02 213.0 100.00 179.0 936 1.73 48.0 0.75
Load Characteristics

  • % of Rated Load
  • Current (Amps)
  • Rated Output (KW)
  • Efficiency (%)
  • Power Factor (%)
  • Speed (RPM)
  • Temp. Rise @ FL
  • Torque (ft-lb)
  • 0 %
  • 1.96
  • 0.271
  • 0.0
  • 60.0
  • 1,200
  • 0.0
  • 0.00
  • 25 %
  • 2.24
  • 0.386
  • 36.1
  • 75.0
  • 1,180
  • 0.0
  • 13.40
  • 50 %
  • 2.60
  • 0.513
  • 54.4
  • 85.4
  • 1,165
  • 0.0
  • 27.00
  • 75 %
  • 3.12
  • 0.654
  • 64.1
  • 91.2
  • 1,145
  • 0.0
  • 41.30
  • 100 %
  • 3.78
  • 0.818
  • 68.4
  • 94.3
  • 1,125
  • 0.0
  • 56.00
  • 125 %
  • 4.67
  • 1.024
  • 68.3
  • 95.4
  • 1,095
  • 0.0
  • 72.00
  • 150 %
  • 6.48
  • 1.410
  • 59.5
  • 94.8
  • 1
  • 0.0
  • 92.90